Enphase M175-24-240-S01/2 Solar Grid-Tie Inverter
Enphase Options:
Communications
Gateway
The module performance information generated by each Micro-inverter is collected by the Enphase communications gateway called the Energy Management Unit (EMU). The Envoy EMU then transmits this data over a broadband internet connection to the Enphase Enlighten website.
Enlighten
The Enphase Enlighten website analyzes the per-module data collected by each Micro-inverter. Enlighten automatically detects any shortfall in energy production, identifies possible causes, and suggests solutions to correct the problem. The Enphase Enlighten website is constantly monitoring and managing every module on every installation.
175W Output for 24V (Nominal) Modules | |
Input Data (DC) | |
Model | M175-24-240 |
Recommended input power (STC) | 210W |
Maximum input DC voltage | 54V |
Peak power tracking voltage | 25V-40V |
Max. DC short circuit current | 10A |
Max. input current | 8A |
Output Data | |
Maximum output power | 175W |
Nominal output current | 750mA |
Nominal voltage/range | 240V/211V-264V |
Extended voltage/range | 240V/206V-269V |
Nominal frequency/range | 60.0/59.3-60.5 |
Extended frequency/range | 60.0/59.2-60.6 |
Power factor | >0.95 |
Maximum units per branch | 16 |
Efficiency | |
Peak inverter efficiency | 95% |
CEC weighted efficiency | 94.5% |
Nominal MPP tracking | 99.6% |
Mechanical Data | |
Operating temperature range | -13°F to 149°F |
Night time power consumption | 580mW |
Dimensions (WxHxD) | 10.5" x 5.5" x 1.5" |
Weight | 4.0 lbs |
Cooling | Natural Convection - No Fans |
Enclosure environmental rating | Outdoor - Nema 6 |
Features | |
Connection | MC1 or
MC4 (Solarline 2) Cables (Model Specific) |
Communication | Powerline |
Warranty | 15 Years |
Compliance | FCC Part 15 Class B |
For Enphase
micro-inverter compatibility on the list of inverters authorized
by the State of California click on the link below:
http://www.gosolarcalifornia.org/equipment/inverters.php
Can these
Enphase solar inverters be used in both Residential and Commercial
solar deployments?
Yes. Enphase micro-inverters are designed for 240VAC residential,
as well as 208VAC three-phase service.
What solar
modules are the Enphase Micro-inverters compatible with?
The Enphase Micro-inverters (Model M200 240V and Model M200 208V)
are designed to work with solar modules up to 65V input.
Other documents,
including user manuals are available at: http://www.enphaseenergy.com/support/downloads.cfm